Changes between Version 9 and Version 10 of LSIMegaRAID


Ignore:
Timestamp:
09/01/08 11:22:39 (16 years ago)
Author:
Adam Cécile
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • LSIMegaRAID

    v9 v10  
    3131= 3. Management and reporting tools =
    3232
     33== 3.1 megactl ==
     34
     35=== 3.1.1. Quickstart and output example ===
     36
     37Print current controller status:
     38{{{
     39server:~# megactl
     40a0       PERC 4/Di                chan:2 ldrv:1  batt:good
     41a0d0      273GiB RAID 5   1x3  optimal
     42a0c0t0     136GiB  a0d0  online
     43a0c0t1     136GiB  a0d0  online
     44a0c0t2     136GiB  a0d0  online
     45}}}
     46
     47There are several switches which are interresting:
     48  * '''-H''': Only print lines which are not ok.[[BR]]If nothing is printer, everything is fine
     49  * '''-B''': Ignore batttery problems when running -H.[[BR]]In fact megactl can define if your controller has a battery or not.[[BR]]If you don't have one, use this parameter.
     50
    3351As theses cards a rather old, many tools exists to monitor and manage them.
    3452[[BR]] The first one is an '''opensource''' tool named '''megactl''' which can be used to report controller and disks status.