Changes between Version 13 and Version 14 of LSIMegaRAIDSAS
- Timestamp:
- 09/01/08 15:48:58 (16 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
LSIMegaRAIDSAS
v13 v14 103 103 {{{ 104 104 server:~# megacli -AdpAllInfo -aAll 105 106 105 Adapter #0 107 106 … … 131 130 }}} 132 131 132 Logical drive 0 on adapter 0 status and type: 133 {{{ 134 server:~# megacli -LDInfo -L0 -a0 135 Adapter 0 -- Virtual Drive Information: 136 Virtual Disk: 0 (Target Id: 0) 137 Name:raid1 138 RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0 139 Size:237824MB 140 State: Optimal 141 Stripe Size: 64kB 142 Number Of Drives:2 143 Span Depth:1 144 Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU 145 Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU 146 Access Policy: Read/Write 147 Disk Cache Policy: Disk's Default 133 148 149 Exit Code: 0x00 150 }}} 134 151 152 Display, disable or enable automatic rebuild on adapter 0: 153 {{{ 154 server:~# megacli -AdpAutoRbld -Dsply -a0 155 156 Adapter 0: AutoRebuild is Enabled. 157 158 Exit Code: 0x00 159 server:~# megacli -AdpAutoRbld -Dsbl -a0 160 161 Adapter 0: AutoRebuild is Disabled. 162 163 Exit Code: 0x00 164 server:~# megacli -AdpAutoRbld -Enbl -a0 165 166 Adapter 0: AutoRebuild is Enabled. 167 168 Exit Code: 0x00 169 }}}